Transformer oil water activity and moisture monitoring

Moisture in transformer oil is measured continuously. Water activity, dissolved water and oil temperature appear on one screen. When a value rises, the screen warns you. Sampling and maintenance are planned in time.

Transformer oil overview screen: water activity 0.62 aw in warning, dissolved water 42 ppm, temperature 24.6 °C
Overview screen: water activity, dissolved water and temperature. Warning and alarm limits appear beside each value. (Turkish interface)

What it measures

  • Water activity (aw): Shows how close the oil is to water saturation, on a scale from 0 to 1.
  • Dissolved water (ppm): Shows how much water the oil contains.
  • Oil temperature (°C): Moisture values are read together with temperature.

Why it matters

Water in transformer oil lowers the oil's insulating strength and speeds up ageing of the paper insulation. Moisture usually rises slowly, through seals, the breather or condensation. Continuous measurement shows the rise without waiting for the next sample date.

Monitoring screen

The screen sits in the panel next to the transformer. It has four pages: overview, trend, predictive maintenance and alarms. The images below are taken from the screen of a working system. The interface shown is in Turkish.

Transformer oil predictive maintenance screen: health summary in warning, recommended action is to take a sample
Predictive maintenance screen: health summary, recommended action and each value's change against its reference (Turkish interface)
Transformer oil alarm log: a high water activity warning listed with date and time
Alarm log: warnings are listed with date and time, acknowledged and exported to a USB drive (Turkish interface)

Screenshots are taken from a working system. The limits shown belong to that system. Limits are set separately for each transformer.

How it works

  1. The sensor is fitted

    The sensor screws into an oil valve or oil line on the transformer. The probe stays in the oil.

  2. Values are monitored

    Water activity, dissolved water and temperature are shown and logged continuously.

  3. A warning appears at the limit

    When a value passes the warning limit, its card gets an amber frame and a warning tag. Past the alarm limit, it is logged as an alarm.

  4. Maintenance is planned

    The screen recommends the next step. For example, when water activity rises it tells you to take a sample.

Sensor and mounting

Moisture-in-oil sensor: threaded connection and the measuring probe inside its perforated guard
Moisture-in-oil sensor: threaded connection and the measuring probe inside its perforated guard

The sensor fits an oil valve or oil line on the transformer with a G3/4 threaded connection. The mounting point is agreed with the person responsible for the transformer during the site survey. Installation is planned under the site's safety rules.

Moisture-in-oil sensor specifications
ParameterValue
Water activity0–1 aw (±⁠0.03)
Dissolved water0–5000 ppm
Oil temperatureMeasured
Supply24 V DC
ProtectionIP66
ConnectionG3/4

Values are from the sensor data sheets. Results in the plant may differ. The full data sheet is available on request.

What we do not measure: dissolved gas analysis (DGA), breakdown voltage, acidity and furans. These tests are done in a laboratory. DataMonitor does not replace them. It works alongside them. The system tracks rising moisture and gives early warning. It does not diagnose faults.

Transformer oil FAQ

What is the difference between water activity and ppm?

Water activity (aw) shows how close the oil is to water saturation, from 0 to 1. The ppm value is the amount of water in the oil. The same ppm value means a higher water activity in cold oil. That is why both values are read together with temperature.

Does online measurement replace laboratory analysis?

No. The laboratory measures water by the Karl Fischer method. It also runs other tests such as dissolved gas and breakdown voltage. Online measurement tracks the period between two samples continuously. When a value rises, it tells you it is time to take a sample.

How are the warning and alarm limits set?

Limits are set at installation, based on the transformer's oil and its normal operating values. Each value has two limits: warning and alarm.

Does the system work without an internet connection?

Yes. Values are shown and logged on the monitoring screen next to the transformer. If you wish, the system connects to an on-premise server or to online monitoring. Monitoring levels

A quote for your machine

The machine, the oil in use and the problem are discussed by phone. The right product and monitoring level are defined. The price is sent as a written quote.

  • Product recommendation for your machine
  • Written quote
  • Installation and alarm set-up included
WhatsApp Call Get a quote