Transformer oil water activity and moisture monitoring
Moisture in transformer oil is measured continuously. Water activity, dissolved water and oil temperature appear on one screen. When a value rises, the screen warns you. Sampling and maintenance are planned in time.

What it measures
- Water activity (aw): Shows how close the oil is to water saturation, on a scale from 0 to 1.
- Dissolved water (ppm): Shows how much water the oil contains.
- Oil temperature (°C): Moisture values are read together with temperature.
Why it matters
Water in transformer oil lowers the oil's insulating strength and speeds up ageing of the paper insulation. Moisture usually rises slowly, through seals, the breather or condensation. Continuous measurement shows the rise without waiting for the next sample date.
Monitoring screen
The screen sits in the panel next to the transformer. It has four pages: overview, trend, predictive maintenance and alarms. The images below are taken from the screen of a working system. The interface shown is in Turkish.
Screenshots are taken from a working system. The limits shown belong to that system. Limits are set separately for each transformer.
How it works
The sensor is fitted
The sensor screws into an oil valve or oil line on the transformer. The probe stays in the oil.
Values are monitored
Water activity, dissolved water and temperature are shown and logged continuously.
A warning appears at the limit
When a value passes the warning limit, its card gets an amber frame and a warning tag. Past the alarm limit, it is logged as an alarm.
Maintenance is planned
The screen recommends the next step. For example, when water activity rises it tells you to take a sample.
Sensor and mounting
The sensor fits an oil valve or oil line on the transformer with a G3/4 threaded connection. The mounting point is agreed with the person responsible for the transformer during the site survey. Installation is planned under the site's safety rules.
| Parameter | Value |
|---|---|
| Water activity | 0–1 aw (±0.03) |
| Dissolved water | 0–5000 ppm |
| Oil temperature | Measured |
| Supply | 24 V DC |
| Protection | IP66 |
| Connection | G3/4 |
Values are from the sensor data sheets. Results in the plant may differ. The full data sheet is available on request.
What we do not measure: dissolved gas analysis (DGA), breakdown voltage, acidity and furans. These tests are done in a laboratory. DataMonitor does not replace them. It works alongside them. The system tracks rising moisture and gives early warning. It does not diagnose faults.
Transformer oil FAQ
What is the difference between water activity and ppm?
Water activity (aw) shows how close the oil is to water saturation, from 0 to 1. The ppm value is the amount of water in the oil. The same ppm value means a higher water activity in cold oil. That is why both values are read together with temperature.
Does online measurement replace laboratory analysis?
No. The laboratory measures water by the Karl Fischer method. It also runs other tests such as dissolved gas and breakdown voltage. Online measurement tracks the period between two samples continuously. When a value rises, it tells you it is time to take a sample.
How are the warning and alarm limits set?
Limits are set at installation, based on the transformer's oil and its normal operating values. Each value has two limits: warning and alarm.
Does the system work without an internet connection?
Yes. Values are shown and logged on the monitoring screen next to the transformer. If you wish, the system connects to an on-premise server or to online monitoring. Monitoring levels
A quote for your machine
The machine, the oil in use and the problem are discussed by phone. The right product and monitoring level are defined. The price is sent as a written quote.
- Product recommendation for your machine
- Written quote
- Installation and alarm set-up included